Silver-coated ventilator tubes cut pneumonia risk

CHICAGO
Tue Aug 19, 2008 4:01pm EDT

CHICAGO (Reuters) - Ventilator tubes treated with silver to reduce infections cut the risk of pneumonia in gravely ill patients by 36 percent compared with similar, untreated tubes, researchers reported on Tuesday.

Health  |  Stocks  |  Regulatory News

The findings, published on Tuesday in the Journal of the American Medical Association, suggest the tubes may offer a way to reduce the incidence of this common and often deadly infection, at least for high-risk patients.

Half of the antibiotics used in hospital intensive care units are prescribed to help prevent bacterial pneumonia in patients put on ventilators to help them breathe, according to a commentary in the journal.

Silver is widely used as an antimicrobial agent and has been shown to reduce bacterial pneumonia infections in animals. Medical device maker C.R. Bard funded the study to see if a silver coating would help reduce the infections in humans.

Dr. Marin Kollef of the Washington University School of Medicine in St. Louis and colleagues tested the devices in 1,500 patients expected to be placed on a ventilator for more than 24 hours between 2002 and 2006.

They found ventilator patients given silver-coated breathing tubes had significantly fewer cases of pneumonia than those with untreated ventilator tubes.

Of the 1,509 patients who had tubes in their trachea for 24 hours or longer, 4.8 percent those with silver-coated tubes developed ventilator-associated pneumonia, compared with 7.5 percent of patients with uncoated tubes.

The antimicrobial tubes also delayed the time it took for ventilator-associated pneumonia to develop compared with those using a similar, uncoated tube, the team found.

But the tubes did not reduce death rates, and the findings were limited because many patients could not provide informed consent, reducing the size and overall power of the study, Dr. Jean Chastre of the Groupe Hospitalier Pitie-Salpetriere in Paris, said in a commentary.

Chastre said the findings suggest high-risk patients may benefit from the devices, but said more study is needed before they are recommended for all ventilator patients.

In November, the U.S. Food and Drug Administration gave Bard clearance to market its silver-coated endotracheal tube, known as Agento, but the company said it would wait to launch the product until its study was published in a major journal.

(Editing by Maggie Fox)



More from Reuters

Photo

RIM profit, outlook top forecasts; shares surge

OTTAWA (Reuters) - Research In Motion posted a big jump in profit and issued an even stronger outlook on Thursday, as sturdy demand from holiday shoppers helped the BlackBerry maker fend off the competition.

Aerospace Industries Association President and CEO Marion Blakey makes remarks during the Reuters Aerospace and Defense Summit, December 16, 2009 in Washington.REUTERS/Mike Theiler

"We're not asking for a bailout"

If the U.S. is serious about creating jobs it should invest in aviation programs, says the chief of the Aerospace Industries Association. Just don't call it a bailout.  Full Article 

President Barack Obama delivers remarks at Lehigh Carbon Community College in Allentown, Pennsylvania, December 4, 2009. REUTERS/Jim Young
Analysis:

Would you give him a B+ too?

"I told Michelle when we got here that in six months my poll numbers will start crashing," says President Obama. He's not worried -- yet.  Full Article